Chinese cabinet factories build to metric modules. Most overseas kitchen layouts, appliance cutouts, and countertop fabricators still work in inches. Neither side is wrong — but the gap between the two systems is where elevation drawings stop matching the cabinets that arrive, where a dishwasher opening comes up 8 millimeters short, and where a forty-unit kitchen run drifts out of square one filler strip at a time. This is what to specify so the schedule you send is the kitchen you receive.
Why the module system matters more than the cabinet style
Buyers spend most of their specification effort on door style, finish, and hardware — reasonably, since that is what a showroom visitor sees first. Dimensional standards get far less attention, partly because they feel like background infrastructure rather than a design decision. That is a mistake with Chinese-sourced cabinetry specifically, because almost every factory building for export designs its carcasses around metric module series, not the three-inch imperial increments that American and many Commonwealth kitchen designers were trained on.
A metric module and an imperial module are both internally consistent systems. The problem only appears at the boundary: when a kitchen designer hands a factory a layout dimensioned in inches, or when a factory quotes a layout back in millimeters rounded to the nearest clean number, a small conversion residue appears at every joint. On a single cabinet that residue is invisible. Across a run of eight, twelve, or forty units set wall to wall, it accumulates into a gap, an overhang, or a cabinet run that stops short of the wall it was meant to reach.
None of this is a defect in Chinese manufacturing. It is a translation problem, and translation problems are solved on the specification sheet, not on the factory floor after the containers have already shipped.
Standard width modules: metric and imperial side by side
Base and wall cabinet widths are built in fixed module series, not arbitrary dimensions. Knowing both series — and where they do and do not overlap — is the first thing to put in front of a factory before a single elevation drawing is approved.
METRIC MODULE MARKS DO NOT SIT ON IMPERIAL MODULE MARKS
| China metric width | Nearest imperial size | Exact imperial equivalent | Gap to absorb |
|---|---|---|---|
| 300mm | 12in | 304.8mm | 4.8mm short |
| 450mm | 18in | 457.2mm | 7.2mm short |
| 600mm | 24in | 609.6mm | 9.6mm short |
| 750mm | 30in | 762mm | 12mm short |
| 900mm | 36in | 914.4mm | 14.4mm short |
| 1200mm | 48in | 1219.2mm | 19.2mm short |
The gap grows with every size step, and it compounds across a run. Six 900mm base units placed where a drawing called for six 36-inch units will fall short of the far wall by roughly 86 millimeters — well over three inches — unless the layout was built around one module system from the start rather than converted partway through.

Depth, height, and toe kick standards
Width gets the most attention because it is what determines how many units fit in a run, but depth and height carry their own standard ranges that a factory will default to unless told otherwise.
STANDARD DIMENSION RANGES BY CABINET TYPE
Toe kick height is worth flagging on its own: a 100mm Chinese toe kick and a 4-inch (101.6mm) US toe kick are close enough to pass casual inspection, but when a countertop fabricator or appliance installer works from a finished-floor-to-countertop height assumption carried over from a domestic spec sheet, a 1.6mm difference at the base compounds with every other rounding error in the run. Specify toe kick height as an exact millimeter figure, not “standard,” on every order.
Appliance cutouts: where rounding errors become real problems
Width modules that come up a few millimeters short are a cosmetic and assembly annoyance. Appliance cutouts that come up short are a different category of problem, because the appliance itself does not compromise. A dishwasher built to a 598mm nominal opening does not get narrower because the cabinet opening was built to the nearest clean metric or imperial round number instead of the appliance manufacturer’s actual cutout spec.
- Dishwasher — most European and Chinese-market dishwashers cut to 598mm wide; most North American models cut to 24in (609.6mm) nominal, built with 596–610mm tolerance. Confirm which appliance brand and model is actually going into the kitchen before the cabinet opening is cut.
- Built-in oven — standard niche width is 560–600mm, but niche height and depth vary meaningfully by brand; pull the installation manual for the exact model, not a generic “standard oven” assumption.
- Cooktop — cutout width typically 560–580mm for a 600mm-class cooktop, but gas models often need a wider clearance behind the cutout for the regulator and control knobs than induction models do.
- Refrigerator surround — built-in and panel-ready refrigerators are sold against a specific niche width, height, and depth tolerance by model; freestanding refrigerators need side and top air-clearance allowances the cabinet schedule must reserve as empty space, not as a cabinet dimension.
- Range hood / extractor — duct routing and housing width above a cooktop run drives the wall cabinet layout on either side; confirm duct diameter and routing path before the wall units either side are finalized.
The reliable method is to request the appliance manufacturer’s own installation PDF for the exact model being installed and pass the cutout dimensions from that document directly to the cabinet factory — not a generic “standard 600mm opening” instruction, and not a dimension copied from a different model in the same product line. Appliance manufacturers revise cutout tolerances between model generations more often than buyers expect.
Two ways to handle the metric-imperial gap
There is no single correct answer to which module system a kitchen should be designed around — it depends on who else touches the project. The comparison below is not a quality judgment; it is a question of which approach fits your supply chain.

Building a cabinet schedule the factory can follow without conversion drift
The fix is procedural, not technical. A clear schedule prevents almost all of the dimension problems described above.
- Pick one unit system for the entire schedule — do not mix millimeter call-outs with inch call-outs on the same elevation drawing, even as a convenience note.
- State filler strip widths explicitly — if a run of metric cabinets is going into an imperial-dimensioned space, name the filler width at each end rather than leaving the factory to decide where the slack goes.
- Attach the actual appliance installation manual for every built-in appliance, not a generic cutout number.
- Confirm toe kick height, depth, and setback as exact numbers, not “standard.”
- Request a full cutting list and elevation back from the factory before production — not after the first sample, and not after the full run has already been cut.
A CONVERSION-SAFE PATH FROM LAYOUT TO PRODUCTION
What goes wrong when this is skipped
The two most common dimensional failures we see are both avoidable with the schedule above. The first is a cabinet run that falls short of or overshoots the wall it was designed to reach, discovered only once the units are on site and the installer realizes the filler strip nobody specified needs to be cut on site, in the wrong finish, under time pressure. The second is an appliance that will not sit in its opening, because the cutout was built to a generic standard dimension instead of the cutout spec for the specific model the client actually bought — sometimes discovered only when the appliance arrives weeks after the cabinets, by which point re-cutting a cabinet box is far more disruptive than it would have been on the drawing.
Both failures trace back to the same root cause: a dimension that was assumed instead of confirmed in writing before cutting began. Neither requires a better factory. Both require a clearer schedule.
Planning a cabinet order and want the dimension schedule checked before it goes to production?